Cabletron Systems 6500 User Manual

Page of 150
SmartSwitch 6500 User Guide   6-3
Virtual Ports and Static Connections
PVC Connections  
However, on a point-to-multipoint connection there should be no traffic in the backward direction, so we define the 
backward traffic descriptor with its Cell Loss Priorities set to zero (0)
Smart6500 # add trafficdescriptor
TrafficType(UBR)                          :   
< This is the backward traffic descriptor
TrafficDescriptorType(11)                 :
PCRCLP01(100)                             : 0 
< Set PCRCLP01 to zero
QOSCLASS(0)                               :
AalType(5)                                :
Smart6500 #
2.
Use 
show trafficdescriptor
 to obtain the new traffic descriptors’ index numbers.
Smart6500 # show trafficdescriptor
========================================================================================
TD#  Traff    Desc  QoS  Peak Cell Rate  Sust Cell Rate  Max Burst Size  Min Cell Aal Type
     Type     Type         (Kb/s)           (Kb/s)           (Kb/s)      Rate     
                         CLP_0  CLP_0+1  CLP_0  CLP_0+1  CLP_0  CLP_0+1  (Kb/s)
=========================================================================================
1    NRTVBR   7     0    0      10872    5436   0        2052   0        0         5
2    CBR      2     1    0      100      0      0        0      0        0         5
3    UBR      11    0    0      100      0      0        0      0        0         5
4    UBR      11    0    0      0        0      0        0      0        0         5
176  NRTVBR   2     1    0      1585     0      0        0      0        0         5
Smart6500 #
In the example above, traffic descriptor three (3) will be used in the forward direction, and traffic descriptor four (4) 
will be used in the backward direction.
3.
Use 
add pvc
 to successively create point-to-multipoint PVCs for ports B2, B3, and C1.
Smart6500 # add pvc
ConnType(PTP)                             : pmp
Port-1-Number()                           : 7a1
Port-1-VPCI()                             : 0
Port-1-VCI()                              : 101
Port-2-Number()                           : 7a2
Port-2-VPCI()                             : 0
Port-2-VCI()                              : 101
Port1-to-Port2TrafficDescriptorIndex()    : 3
Port2-to-Port1TrafficDescriptorIndex()    : 4
Smart6500 #
4.
Perform step 3 for ports 7a3 and 7a4.
5.
Connect the workstations to their respective ports.
6.
Configure the workstations for the same subnet and VPCI/VCI pair = 0/101.
The broadcasting workstation on port 7a1 can send traffic to the receiving workstations on ports 7a2, 7a3, and 7a4.