Cabletron Systems 6E132-25 User Manual

Page of 184
Chapter 5: Local Management
5-86
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
Figure 5-30
Port Redirect Function Screen 
The following definitions briefly explain each field of the Port Redirect 
Function screen:
Source Port (Read-only)
Shows which ports are currently set as source ports.
Destination Port (Read-only)
Shows which ports are currently set as destination ports.
Remap Errors (Read-only)
Displays whether the corresponding source ports are configured to send 
errored frames to the destination ports, or to drop all errored frames 
before forwarding traffic.
Source Port [
n] (Selectable)
Allows a selected port [n] to be changed to a source port.
Destination Port [
n] (Selectable)
Allows a selected port [n] to be changed to a destination port.
Firmware Revision:      XX.XX.XX
Port Redirect Function
1960_22
BOOTPROM Revision: XX.XX.XX
Source Port:
        1
        1
        1
        2
        2
        3
        3
        3
Destination Port:
            2
            3
            4
            1
            3
            4
            5
            6
Module Type: 6E122-26
Slot Number: 
X
Remap Errors:
            ON
            ON
            ON
            OFF
            OFF
            ON
            ON
            ON
============
============
============
6E122-26 LOCAL MANAGEMENT
Event Message Line
SAVE
PREVIOUS
RETURN
RETURN
NEXT
Source Port [1]
Destination Port [1]
Status   [ADD]
EXIT
Errors   [ON]