Lantronix 900-510 User Manual

Page of 280
8: Device Ports 
SLB™ Branch Office Manager User Guide 
 
93 
Infeed Status 
Click the link to view the status of the data the SLP power 
manager is receiving. 
System Info 
Click the link to see system information pertaining to the SLP 
device. 
SLP Commands 
Restart SLP 
To restart the SLP power manager, select the checkbox. 
Control Outlet 
For Tower A or Tower B, select All Outlets or Single Outlet 
and the number of the outlet to be controlled (1-8 for the 
SLP8 power manager or 1-16 for the SLP16 power manager) 
and select the command for the outlet (No Action, Power On, 
Power Off, Cycle Power). No Action is the default. 
2.  Click the Apply button. 
Device Port – Sensorsoft Device 
Devices made by Sensorsoft are used to monitor environmental conditions. 
1.  In the Connected to field above the IP Settings section of the Device Ports – 
Settings page, select Sensorsoft.
 
2.  Click the Device Commands link. The following page displays:
 
 
3.  Select a port and enter or view the following information: 
Device Port (view 
only) 
Number of the SLB port. 
Device Name (view 
only) 
Name of the SLB port. 
Temp (°C) 
Current temperature (degrees Celsius) on the device the 
sensor is monitoring.  
Low Temp 
Enter the temperature (degrees Celsius) permitted on the 
monitored device below which the SLB branch office 
manager sends a trap. 
High Temp 
Enter the temperature (degrees Celsius) permitted on the 
monitored device above which the SLB device sends a trap.