Installing the Device
Installation
3-3
3.3.1
Tabletop or Shelf Installation
The following two subsections provide guidelines for installation on a tabletop or shelf.
Guidelines for Tabletop and Shelf Installations
Tabletop and shelf installations must be within reach of the network cabling and meet the 
requirements listed below:
Locate the 2H253-25R within seven feet of an appropriately grounded power receptacle that 
meets the power supply requirements listed in 
In a shelf installation, the shelf must support 13.5 kg (30 lb) of static weight for each 
2H253-25R.
Maintain a temperature of between 5°C (41°F) and 40°C (104°F) at the installation site with 
fluctuations of less than 10°C (18°F) per hour.
Maintain a 2-inch clearance from the left, right, and rear sides of the device to provide adequate 
ventilation.
Installation
For a tabletop or shelf installation, locate the 2H253-25R within seven feet of its power source and 
on an unrestricted free surface area as shown in 
 for power 
connection instructions.
!
CAUTION
To ensure proper ventilation and prevent overheating, leave a minimum clearance space 
of 5.1 cm (2.0 in) at the left, right, and rear of the 2H253-25R.