Cisco Systems N5KC5548UPFA User Manual

Page of 168
S e n d   d o c u m e n t a t i o n   c o m m e n t s   t o   n e x u s 5 k d o c s @ c i s c o . c o m .
4-4
Cisco Nexus 5500 Platform and Cisco Nexus 5000 Platform Hardware Installation Guide
OL-15902-01
Chapter 4      Replacing Components
  Replacing an I/O Module for a Cisco Nexus 5548 Switch
Figure 4-4
Removing the I/O Module from the Chassis
Step 7
Place the removed I/O module on the antistatic surface.
Step 8
On the remaining fan tray in the I/O module, loosen its captive screw so that it is no longer attached to 
the I/O module. 
Step 9
Pull the fan tray out of the I/O module.
You are ready to install a replacement I/O module as explained in the 
.
Installing an I/O Module
To install an I/O module in a Cisco Nexus 5548 chassis, follow these steps:
Step 1
Align the replacement I/O module to the I/O module slot in the chassis and push the module all the way 
into the slot so that its two captive screws are aligned to their holes in the chassis.
Step 2
Tighten both captive screws to the chassis.
Step 3
Install both fan modules into the replacement I/O module (see th
).
1
239215
1
Pull the handle on the left fan module to completely 
remove the I/O module from the chassis.