Cisco Nexus 5500 Platform and Cisco Nexus 5000 Platform Hardware Installation Guide
OL-15902-01
Chapter 4      Replacing Components
  Replacing or Installing Power Supplies
Figure 4-7
Positioning the Module in the Cisco Nexus 5010
 
Chassis
Replacing or Installing Power Supplies
The Cisco Nexus 5500 Platform switches and the Cisco Nexus 5000 Platform switches support two 
front-end AC or DC power supplies, but may be used with one power supply. The switches each require 
one power supply, but you can include a second power supply for power redundancy. If you use only one 
power supply, you must fill the second power supply slot with a blank module to maintain the designed 
airflow.
If you need to replace an existing power supply, follow the procedures that explain how to remove and 
install power supplies. If you are installing a new power supply where one did not exist before, follow 
the installation procedure.
Note
The airflow direction must be the same for all power suply and fan modules in the chassis. You can order 
all modules with front to back airflow but you can alternatively order back to front airflow for the Cisco 
Nexus 5548UP switch modules. Back to front airflow modules have a black stripe.Make sure that all 
modules have either a black strip for back to front or no stripe for front to back. 
This section includes the following topics:
Note
You can replace a faulty power supply while the system is operating if the other power supply is 
functioning.