27
Stop Bits: 1
Flow control: None 
For the VFrame Evaluation Test Plan, continue to 
 of 
in th
Boot your Topspin 360 and Configure Basic 
Connectivity
To configure basic connectivity, you must power-on the Server Switch and configure it with the Serial 
Console port and a terminal or workstation. To configure basic Ethernet connectivity, you can apply a 
static IP address to the Topspin 360, or you can configure the chassis to obtain an IP address from a 
DHCP server.
To power-on and configure your Topspin 360, perform the following steps:
1. Use the serial cable (provided) to connect the serial console port of the Controller Card in slot one 
of your Topspin 360 to a terminal or to a workstation that runs terminal-emulation software.
2. Launch a terminal session with the following parameters:
Baud: 9600 bps
Data Bits: 8
Parity:  None
Stop Bits: 1
Flow control: None 
3. Connect a power cord to your Topspin 360, then plug the cord in to an appropriate power source. 
The Topspin 360 boots.
4. After the system boots, press the Enter key several times to display the CLI login prompt.
Example
5. Enter super as your user ID and password to log in as a user with administrative privileges.
Example
Assign a Static IP Address
To configure basic Ethernet connectivity, perform the following steps:
1. Enter the enable command.
Example
2. Enter the configure command.
Example
Login:
Login: super
Password: super
Topspin-360>
Topspin-360> enable
Topspin-360#
Topspin-360# configure
Topspin-360(config)#