Carson SWITCH CONTROL BOX Leaflet

Page of 2
CP4914C 
Page 1 of 2 
08/08/05 
 
 
Carson Manufacturing Co., Inc. 
5451 North Rural Street 
Indianapolis, IN  46220 
Phone: (888) 577-6877    Fax: (317) 254-2667 
www.carsonsirens.com 
 
SB-008-10 
SWITCH CONTROL BOX 
INSTALLATION AND OPERATING INSTRUCTIONS 
 
SPECIFICATIONS 
Input Voltage 
10 - 16 VDC (negative ground) 
Input Current 
160 AMPS Max.  (80 AMPS for Switch 1 – 4; 80 AMPS for switch 5 – 8) 
Output Current 
20 AMPS each,  each output protected with internal fuse. 
Option to combine Output 1 and 2 for 40 AMP total output on switch 1 or 2. 
Operating Temperature 
-15° F to +140°F 
Controls 
(8) ON/OFF push-button switches with backlit changeable legends.  Legend changes color when activated. 
Internal option switch combines switch 1 and 2.  When switch 1 or 2 is pressed, both outputs 1 and 2 activate. 
Internal option switch changes switch 8 to momentary.  Output 8 is activated for 10 seconds nominal. 
Connections 
(2) Positive #6AWG Wire Power Input, (2) Four Position Harness #10AWG Wire Output 
(1)Positive and Negative Plug #22AWG Wire to power internal electronics and backlight. 
Size 
6-1/8" Wide, 1-3/8" High, 6-1/2" Deep 
Weight 
2 –1/2 LBS. 
 
NOTICE 
Due to continuous product improvements, we must reserve the right to change any specifications and information, contained in this manual at 
any time without notice. 
Carson Manufacturing Co., Inc. makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties 
of merchantability and fitness for a particular purpose. 
Carson Manufacturing Co., Inc. shall not be liable for errors contained herein or for incidental or consequential damages in connection with the 
furnishing, performance, or use of this manual.  
 
 
RETURN 
If you have any questions concerning this or any other Carson product, please contact our Technical Service Department at 
(888) 577-6877.  Many issues can be handled over the phone.  We can also be reached via e-mail at service@carsonsirens.com 
 
If a product must be returned for any reason, please contact our Technical Service Department to obtain a Returned Merchandise 
Authorization number (RMA#) before you ship the product to Carson.  Please write the RMA# clearly on the package near the mailing label.  
Be sure to provide a return address, contact and phone number, along with a brief description of the problem. 
LIMITED WARRANTY 
Carson Manufacturing Company, Inc. warrants this new product to be free from defects in material and workmanship, under normal use and service, for a period of five (5) years from the 
date of delivery to the first user-purchaser. 
 
During this warranty period the obligation of Carson Manufacturing is limited to repairing or replacing, as Carson Manufacturing may elect, any part or parts of such product which after 
examination by Carson Manufacturing is determined to be defective in material and/or workmanship.  This warranty does not cover labor charges for removal or re-installation of the 
product.  Fuses and lamps are not covered under this warranty.  This warranty does not extend to any unit that has been subjected to abuse, misuse, improper installation or which has
not been adequately maintained, nor to units which have problems related to service or modification at any facility other than the manufacturer. 
 
THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE.  IN NO EVENT SHALL CARSON MANUFACTURING COMPANY, INC. BE LIABLE FOR ANY LOSS OF PROFITS OR ANY INDIRECT OR 
CONSEQUENTIAL DAMAGES ARISING OUT OF ANY SUCH DEFECT IN MATERIALS OR WORKMANSHIP.