Pelco C1528M-F User Manual

Page of 106
 
22
C1528M-F (6/05)
 
KBD100, KBD200A, AND KBD300A SERIES KEYBOARDS
 
You can connect up to eight KBD100/200A/300A Series keyboards to any of the following ports: 
 
 
COM 5 (1 direct-powered keyboard or up to 8 remotely connected keyboards)
 
 
COM 6 (1 direct-powered keyboard or up to 8 remotely connected keyboards)
 
 
COM 7 (up to 8 remotely connected keyboards)
 
 
COM 8 (up to 8 remotely connected keyboards)
The total number of KBD100/200A/300A Series keyboards connected to the CM6800E cannot exceed 16.
 
KBD100, KBD200A, and KBD300A: Direct-Powered Keyboards 
 
Use COM 5 and 6 (Serial Ports 5 and 6) for direct-powered local keyboards. Each port can power one KBD100/200A/300A Series keyboard.
If you are connecting more than one keyboard to COM 5 or 6, a KBDKIT(-X) is required for each keyboard. Refer to the 
 
KBD100, KBD200A, and 
KBD300A: Remote Keyboards
 
 section.
1. Using the 25-foot (7.62 m) straight data cable supplied with the keyboard, plug one end into the RJ-45 connector on the rear of the 
keyboard. 
 
NOTE:  
 
If distance between CM6800E and keyboard exceeds 25 feet, use KBDKIT(-X).
 
Figure 14.  
 
Data Cable Plugged into Local Keyboard
 
2. Plug the other end of the data cable into either COM 5 or 6 on the CM6800E.
 
Figure 15.  
 
Data Cables Plugged into COM 5 and 6
DEFAULT (ADDRESS 0) DIP SWITCH SETTINGS
(SHIPPED FROM FACTORY)
DIP SWITCHES 1-8 OFF  
KBD300A
1
2
3
4
5
6
7
8
16
8
7
6
32
31
4
3
2
120/230~
50/60 HZ
25 WATTS
  
1 2 3 4 5 6 7 8
CONTROL  
A T
+
T
-
R
+
R
-
T
+
T
-
R
+
R
-
B
1
2
F
3
1
010101
KBD100, 200A, 300A
RJ-45 PIN-OUTS
1  Tx+
2  Tx-
3  12V
4  12V
5  GROUND
6  NC
7  Rx-
8  Rx+
CM6800E-48X8
COM 5&6
1  Rx+
2  Rx-
3  KBD 12V
4  KBD GROUND
5  GROUND
6  NC
7  Tx-
8  Tx+
KBD100, KBD200A, KBD300A
KBD100, KBD200A, KBD300A