Pelco C1528M-F User Manual

Page of 106
32
C1528M-F (6/05)
CONNECTING GENEX MULTIPLEXERS
Use COM 4 to connect up to eight Genex Multiplexers to the CM6800E. 
1. Connect the COM IN port of the multiplexer to COM 4 on the CM6800E, using the 6-foot (1.8 m) reversed data cable supplied with the 
CM6800E. 
One reversed cable and four straight cables are supplied with the CM6800E. Use the reversed cable for connecting the Genex multiplexer 
to the CM6800E.
A straight data cable is supplied with the Genex multiplexer. Use this cable for connecting a second Genex multiplexer to the first 
multiplexer, if necessary.
2. Connect the MAIN monitor output from the multiplexer to any of the 48 camera inputs on the CM6800E.
3. Connect cameras to the multiplexer and then loop them to the CM6800E. Refer to the MX4000 Genex Series Simplex and Duplex 
Multiplexers Installation/Operation Manual for detailed camera connection instructions. Terminate the video loop at the CM6800E.
4. If required, you can connect a total of eight Genex multiplexers through COM 4. Daisy-chain the multiplexers by connecting a straight data 
cable from the COM OUT port on the first multiplexer to the COM IN port on the second multiplexer; connect the COM OUT port on the 
second multiplexer to the COM IN port on the third multiplexer. Continue to the eighth multiplexer, if necessary.
Refer to the System Start-Up section for additional configuration steps required when using a Genex Multiplexer.
Figure 25.  Connecting Genex Multiplexers
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
8
7
6
5
48
47
46
45
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
41
42
43
44
4
3
2
1
ALT
120/230~
50/60 HZ
25 WATTS
  
1 2 3 4 5 6 7 8
CONTROL  
A T
+
T
-
R
+
R
-
T
+
T
-
R
+
R
-
B
1
2
F
3
HZ
75
1
010101
VCR 
AUX 
MAIN 
SPOT 
SVHS 
 
            
OUT    
IN 
 
SVHS 
 
IN     COM    OUT 
N  N 
  
O C C S 
ALARMS 
1  2  3  4  5     
6  7   8   9 10 11 
14 15 16 
12 13 
110-240V 50/60 Hz 
VCR 
AUX 
MAIN 
SPOT 
SVHS 
 
            
OUT    
IN 
 
SVHS 
 
IN     COM    OUT 
N  N 
  
O C C S 
ALARMS 
1  2  3  4  5     
6  7   8   9 10 11 
14 15 16 
12 13 
110-240V 50/60 Hz 
VCR 
AUX 
MAIN 
SPOT 
SVHS 
 
            
OUT    
IN 
 
SVHS 
 
IN     COM    OUT 
N N 
  
O C C S 
ALARMS 
1  2  3  4  5     
6  7   8   9 10 11 
14 15 16 
12 13 
110-240V 50/60 Hz 
GENEX MULTIPLEXER
RJ-45 PIN-OUTS
 Rx+
 Rx-
 NC
 NC
 GROUND
 NC
 Tx-
 Tx+
CM6800E-48X8 COM 4
RJ-45 PIN-OUTS
GENEX MULTIPLEXERS-8 MAXIMUM
 
GENEX MULTIPLEXER 
 
GENEX MULTIPLEXER 
 
GENEX MULTIPLEXER 
 







8   
REVERSED CABLE
MONITOR SIGNAL OUT
 







8   
 Rx+
 Rx-
 12VAC (OUT)
 12VAC 
 GROUND
 NC
 Tx-
 Tx+
(OUT)
STRAIGHT CABLE
STRAIGHT CABLE