Pelco c1515m-a User Manual

Page of 86
Pelco Manual C1515M-A (11/01)
49
Figure 37.  Access the Set Auxiliary Screen
MODE:
For each auxiliary select the operation mode.
OPTIONS:
ALM =
activate the auxiliary as a response to an alarm; if you select
this mode, specify the monitor number and dwell time
LAT =
latching operation
MOM = momentary operation
Specify values for the MON and DWL fields only when you select ALM in the MODE field.
MON:
Specify the number of the monitor the auxiliary will follow (01-08).
DWL:
Specify the amount of time the auxiliary will remain active after there is
no longer an alarm displayed on a monitor (01-99 seconds). The alarm
is displayed on a monitor until
the alarm is acknowledged manually (if MANUAL is selected in
the alarm contact ACK TYPE field),
the alarm contact times out (if AUTO is selected in the alarm
contact ACK TYPE field).
Refer to the ACK TYPE description in 
Internal and External Alarms
 and
in 
Video Loss Alarm
.
PELCO SWITCHER
MODEL CM6800
MAIN MENU
1
CAMERA
2
LOGICAL CAMERA
3
MONITOR
4
ACCESS
5
TIME & DATE
6
PORT
7
PRIORITY
8
SEQUENCE
9
MACRO
10
ALARM CONTACTS
11
EVENT TIMER
12
SET AUXILIARY
13
SET PASSWORD
14
ABOUT CM6800
ENGLISH
RETURN
00654
SET AUXILIARY MENU
AUX
MODE
MON
DWL
1
ALM
01
10
2
LAT
02
43
3
MOM
03
20
RETURN
00643
AUXILIARY OUTPUTS
The three local auxiliary (AUX) outputs on the rear panel of the CM6800 can be operated
manually from a system keyboard or automatically in response to an alarm.
Auxiliar
y
Pr