DELL S6000-ON User Manual
![DELL](https://files.manualsbrain.com/attachments/2e2ed634a275b6b98ad69257c58632e179ac1658/common/fit/150/50/0b94a25108df4a3b962d3b8aa65fc4eda1ead8e68832a26b3f5ed6aa6a0b/brand_logo.png)
snmp authentication SNMP_AUTH_FAIL:SNMP Authentication failed.Request with
invalid community string.
snmp coldstart SNMP_COLD_START: Agent Initialized - SNMP COLD_START.
SNMP_WARM_START:Agent Initialized - SNMP WARM_START.
snmp linkdown PORT_LINKDN:changed interface state to down:%d
snmp linkup PORT_LINKUP:changed interface state to up:%d
Enabling a Subset of SNMP Traps
You can enable a subset of Dell Networking enterprise-specific SNMP traps using one of the following
listed command options.
To enable a subset of Dell Networking enterprise-specific SNMP traps, use the following command.
• Enable a subset of SNMP traps.
snmp-server enable traps
NOTE: The envmon option enables all environment traps including those traps that are enabled
with the envmon supply, envmon temperature, and envmon fan options.
with the envmon supply, envmon temperature, and envmon fan options.
Example of Dell Networking Enterprise-specific SNMP Traps
envmon
envmon
STACK_STATE: Stack unit %d is in Active State
STACKUNITUP: Stack unit 0 is up
envmon
CARD_SHUTDOWN: %sLine card %d down - %s
CARD_DOWN: %sLine card %d down - %s
LINECARDUP: %sLine card %d is up
CARD_MISMATCH: Mismatch: line card %d is type %s - type %s required.
RPM_STATE: RPM1 is in Active State
RPM_STATE: RPM0 is in Standby State
RPM_DOWN: RPM 0 down - hard reset
RPM_DOWN: RPM 0 down - card removed
HOT_FAILOVER: RPM Failover Completed
SFM_DISCOVERY: Found SFM 1
SFM_REMOVE: Removed SFM 1
MAJOR_SFM: Major alarm: Switch fabric down
MAJOR_SFM_CLR: Major alarm cleared: Switch fabric up
MINOR_SFM: MInor alarm: No working standby SFM
MINOR_SFM_CLR: Minor alarm cleared: Working standby SFM present
TASK SUSPENDED: SUSPENDED - svce:%d - inst:%d - task:%s
RPM0-P:CP %CHMGR-2-CARD_PARITY_ERR
ABNORMAL_TASK_TERMINATION: CRASH - task:%s %s
CPU_THRESHOLD: Cpu %s usage above threshold. Cpu5SecUsage (%d)
CPU_THRESHOLD_CLR: Cpu %s usage drops below threshold. Cpu5SecUsage (%d)
MEM_THRESHOLD: Memory %s usage above threshold. MemUsage (%d)
MEM_THRESHOLD_CLR: Memory %s usage drops below threshold. MemUsage (%d)
DETECT_STN_MOVE: Station Move threshold exceeded for Mac %s in vlan %d
CAM-UTILIZATION: Enable SNMP envmon CAM utilization traps.
envmon supply
PEM_PRBLM: Major alarm: problem with power entry module %s
PEM_OK: Major alarm cleared: power entry module %s is good
MAJOR_PS: Major alarm: insufficient power %s
MAJOR_PS_CLR: major alarm cleared: sufficient power
MINOR_PS: Minor alarm: power supply non-redundant
MINOR_PS_CLR: Minor alarm cleared: power supply redundant
874
Simple Network Management Protocol (SNMP)