DELL PC6224F User Manual

Page of 1356
sFlow Commands
1213
Default Configuration
There are no pollers configured by default.
The default poll interval is 0.
Command Mode
Interface Configuration (Ethernet) mode
User Guidelines
This command has no user guidelines.
Example
console(config-if-1/g2)#sflow 1 polling 6055
sflow sampling
Use the sflow sampling command to enable a new sflow sampler instance for 
this data source if rcvr_idx is valid. Use the “no” form of this command to 
reset sampler parameters to the default.
Syntax
sflow 
rcvr-index sampling ethernet  interfaces sampling-rate [size]
no sflow 
rcvr-index sampling ethernet interfaces
rcvr-index—The sFlow Receiver for this sFlow sampler to which flow 
samples are to be sent.  If no receiver is configured, then no packets will be 
sampled.  Only active receivers can be set.  If a receiver expires, then all 
samplers associated with the receiver will also expire.  (Range: 1–8).
interfaces — The list of interfaces to poll.
sampling-rate—The statistical sampling rate for packet sampling from this 
source.  A sampling rate of 1 counts all packets.  A rate of 0 disables 
sampling.  A value of n means that out of n incoming packets, 1 packet will 
be sampled.  (Range: 1024–65536).
size—The maximum number of bytes that should be copied from the 
sampler packet (Range: 20–256 bytes).