DELL PC6224F User Manual
![DELL](https://files.manualsbrain.com/attachments/2e2ed634a275b6b98ad69257c58632e179ac1658/common/fit/150/50/0b94a25108df4a3b962d3b8aa65fc4eda1ead8e68832a26b3f5ed6aa6a0b/brand_logo.png)
SNMP Commands
1245
•
view-name — Specifies the label for the view record that is being created
or updated. The name is used to reference the record. (Range: 1-30
characters.)
•
oid-tree — Specifies the object identifier of the ASN.1 subtree to be
included or excluded from the view. To identify the subtree, specify a text
string consisting of numbers, such as 1.3.6.2.4, or a word, such as
system
system
. Replace a single subidentifier with the asterisk (*) wildcard to
specify a subtree family; for example 1.3.*.4.
• included — Indicates that the view type is included.
• excluded — Indicates that the view type is excluded.
• excluded — Indicates that the view type is excluded.
Default Configuration
A view entry does not exist.
Command Mode
Global Configuration mode
User Guidelines
This command can be entered multiple times for the same view record.
Examples
The following example creates a view that includes all objects in the MIB-II
system group except for sysServices (System 7) and all objects for interface 1
in the MIB-II interface group.
console(config)# snmp-server view user-view system
included
console(config)# snmp-server view user-view system.7
excluded
console(config)# snmp-server view user-view
ifEntry.*.1 included