DELL MXL 10 User Manual

Page of 27
Stacking Dell Force10 MXL 10/40G Switches 
  
15
  
Note: When creating stack ports on an MXL, all ports must be fixed or on the expansion module.  Mixing 
fixed and expansion module ports in order to stack is not supported.
 
Maximum stack-group per unit
 
 
A  maximum  of  4  stack-groups  per  unit  can  be  configured.  In  a  ring  topology,  that  would  be  2  stack-
groups in each direction, i.e 80Gbps stacking bandwidth. In a two unit stack, a maximum of 4 stack-
groups between the two  units  (i.e 160Gbps stacking  bandwidth) is allowed.  Trying  to configure more 
than 4 stack-groups results in the error shown here. 
 
FTOS(conf)#do show system stack-unit 1 stack-group configured  
Configured stack groups in stack-unit 1 
------------------------------------------ 




FTOS(conf)#stack-unit 1 stack-group 4                      
% Error: Max stacking bandwidth for a unit is reached. 
Cabling the stack 
 
After setting these values save the configuration on each switch and reload each switch. Once all 
switches to be used in the stack have reloaded, attach the stacking cables in a supported topology 
using the MXL 40G-QSFP+ ports.   It is recommended to attach the Master and Standby (based on 
priority or MAC address) first, then attach cables to the other members. As each cable is attached and 
each unit joins the stack for the first time, notice that the first available Unit-ID (0-5) is assigned to 
that unit, and the configuration for that unit is added into the running-configuration of the stack. Upon 
subsequent reloads, the unit-ID is retained by each stack member. 
 
If a new member with a higher Priority than the current Master joins the stack, it will become the 
Master of that stack.  As cables are added and units join, the stack is dynamically built with the highest 
priority switch becoming or staying the Master.  The fastest and most efficient way to build the stack is 
to connect the Master and Standby first so the stack will not go into a Master re-election when it finds 
the higher Priority/MAC.     
Validation 
Issue the show system brief command to see the unit IDs present in the stack. 
 
FTOS#show system brief 
Stack MAC : 00:1e:c9:f1:00:7b 
Reload Type : jump-start [Next boot : normal-reload] 
--  Stack Info  -- 
 
 
Unit  UnitType     Status        ReqTyp              CurTyp              Version       Ports 
---------------------------------------------------------------------------------------------------  
0   Management  online        MXL-10/40GbE    MXL-10/40GbE    8.3.16.0E0   56