DELL MXL 10 User Manual

Page of 27
Stacking Dell Force10 MXL 10/40G Switches 
  
19
  
Image upgraded to all 
 
4.  Verify the new firmware was copied to all stack members. 
   
FTOS#show boot system stack-unit all 
Current system image information in the system: 
============================================= 
Type          Boot Type     A                        B 
---------------------------------------------------------------- 
Stack-unit 0  FLASH BOOT    8.3.15.0[boot]         8-3-16-0 
Stack-unit 1  FLASH BOOT    8.3.15.0[boot]         8-3-16-0 
Stack-unit 2  FLASH BOOT    8.3.15.0[boot]         8-3-16-0 
Stack-unit 3  FLASH BOOT    8.3.15.0[boot]         8-3-16-0 
Stack-unit 4  FLASH BOOT    8.3.15.0[boot]         8-3-16-0 
Stack-unit 5  FLASH BOOT    8.3.15.0[boot]         8-3-16-0 
 
5.  Configure the stack to boot to the new firmware file (B in this example), then save the 
configuration. 
 
FTOS#config 
FTOS(conf)#boot system stack-unit all primary system b: 
FTOS(conf)#exit 
FTOS#copy running-config startup-config 
File with same name already exist. 
Proceed to copy the file [confirm yes/no]: yes 

11910 bytes successfully copied 
Synchronizing data to peer Stack-unit 
!!!! 
... 
6.  Reload the stack to activate the new firmware.  
 
FTOS#reload 
Proceed with reload [confirm yes/no]: yes 
 
      Wait for reload to complete.  This may take a few minutes longer than upgrading a single  
      switch.   
 
7.  Verify the new firmware is active on all stack members.