SONET/SDH
www.dell.com | support.dell.com
Figure 49-2. 
wanport
 command example
Figure 49-3.  show
 controllers tengigabitEthernet
 command example
SONET Alarm Reporting
SONET equipment detects events and alarms at each of SONET's three layers—section, line, and path. 
Typically, a SONET device sends alarms both upstream and downstream to notify other devices of the 
problem condition. The GR-253-CORE Synchronous Optical Network (SONET) Transport Systems 
Common Generic Criteria specification defines several alarms: 
Section Loss of Signal (SLOS)
Section Loss of Frame (SLOF)
Alarm Indication Signal - Line (AIS-L)
Signal Degrade Bit Error Rate (SD-BER)
Signal Failure Bit Error Rate (SF-BER)
Remote Defect Indication - Line (RDI-L)
interface TenGigabitEthernet 13/0
 no ip address
 no shutdown
FTOS(conf-if-te-13/0)#
FTOS(conf-if-te-13/0)#wanport 
% Error: Port should be in shutdown mode, config ignored Te 13/0.
FTOS(conf-if-te-13/0)#
FTOS(conf-if-te-13/0)#shutdown 
FTOS(conf-if-te-13/0)#
error due to no shutdown state
FTOS(conf-if-te-13/0)#exit
FTOS#show controllers te 13/0
Interface is TenGigabitEthernet 13/0 
SECTION
LOF = 0    LOS = 0                              BIP(B1)  = 13
LINE
AIS = 0    RDI = 1               FEBE = 7633    BIP(B2) = 19264
PATH
AIS = 0    RDI = 0    LOP = 0    FEBE = 8554    BIP(B3) = 15685
Active Defects:  LRDI
Active Alarms:   LRDI
Alarm reporting enabled for:  SLOS SLOF B1-TCA LAIS LRDI B2-TCA PAIS PRDI PLOP B3-TCA SD SF
 
 Framing is SONET, AIS-shut is enabled
Enabled Alarms are listed here (default is none)