Stacking S-Series Switches
www.dell.com | support.dell.com
To display the status of the stacking ports, including the topology:
 shows the same stack converted to a ring by 
connecting stack-port 2/51 to 0/51; you may rearrange the stacking cables without triggering a unit reset, 
so long as the stack manager is never disconnected from the stack.
Figure 50-9.  Displaying the S-Series Stacking Topology
Figure 50-10.  Displaying the S-Series Stacking Topology
Stacking Cable Redundancy
You can connect two units with two stacking cables as shown in, in case of a stacking port, module, or 
cable failure. Removal of only one of the cables does not trigger a reset.
Task
Command Syntax
Command Mode
Display the stacking ports.
show system stack-ports
EXEC Privilege
Stack#show system stack-ports
Topology: Daisy chain
Interface  Connection    Link Speed      Admin     Link     Trunk
                           (Gb/s)        Status    Status   Group
------------------------------------------------------------------
 0/51                      12             up        down
 0/52        1/50          12             up        up
 1/49        2/52          12             up        up
 1/50        0/52          12             up        up
 2/51                      12             up        down
 2/52        1/49          12             up        up
FTOS#show system stack-ports
Topology: Ring
Interface  Connection    Link Speed      Admin     Link     Trunk
                           (Gb/s)        Status    Status   Group
------------------------------------------------------------------
 0/51        2/51          12             up        up
 0/52        1/50          12             up        up
 1/49        2/52          12             up        up
 1/50        0/52          12             up        up
 2/51        0/51          12             up        up
 2/52        1/49          12             up        up