DELL S50V User Manual
![DELL](https://files.manualsbrain.com/attachments/2e2ed634a275b6b98ad69257c58632e179ac1658/common/fit/150/50/0b94a25108df4a3b962d3b8aa65fc4eda1ead8e68832a26b3f5ed6aa6a0b/brand_logo.png)
C-Series Debugging and Diagnostics | 1183
Hardware watchdog timer
The hardware watchdog command automatically reboots an FTOS switch/router with a single
RPM that is unresponsive. This is a last resort mechanism intended to prevent a manual power
cycle.
RPM that is unresponsive. This is a last resort mechanism intended to prevent a manual power
cycle.
.1.3.6.1.4.1.6027.3.1.1.2.1.1.2
chSysPowerSupplyOperStatus
Each entry in the chSysPowerSupplyTable includes
a set of objects which describe the status of a
particular power supply.
a set of objects which describe the status of a
particular power supply.
.1.3.6.1.4.1.6027.3.1.1.4.0.13
chAlarmPowerSupplyDown
Trap generated when the power supply status
changes to non-operational
changes to non-operational
.1.3.6.1.4.1.6027.3.1.1.4.0.17
chAlarmPowerSupplyClear
Trap generated when the power supply status
changes to operational.
changes to operational.
.1.3.6.1.4.1.6027.3.1.1.4.0.32
chAlarmMajorPS
Trap generated when a power supply major alarm is
issued
issued
.1.3.6.1.4.1.6027.3.1.1.4.0.33
chAlarmMajorPSClr
Trap generated when a power supply major alarm is
cleared
cleared
.1.3.6.1.4.1.6027.3.1.1.4.0.34
chAlarmMinorPS
Trap generated when a power supply minor alarm is
issued
issued
.1.3.6.1.4.1.6027.3.1.1.4.0.35
chAlarmMinorPSClr
Trap generated when a power supply minor alarm is
cleared
cleared
Fan Tray
.1.3.6.1.4.1.6027.3.1.1.2.2.1.2
chSysFanTrayOperStatus
Each entry in the chSysFanTrayTable includes a set
of objects that describe the status of a particular fan
tray, as identified by the chSysFanTrayIndex
of objects that describe the status of a particular fan
tray, as identified by the chSysFanTrayIndex
.1.3.6.1.4.1.6027.3.1.1.4.0.36
chAlarmMinorFanBad
Trap generated when the status of one or more fans
changes to down, and generates a minor alarm
changes to down, and generates a minor alarm
.1.3.6.1.4.1.6027.3.1.1.4.0.21
chAlarmMinorFanBadClear
Trap generated when the minor alarm on the one or
more fans is cleared
more fans is cleared
.1.3.6.1.4.1.6027.3.1.1.4.0.16
chAlarmFanTrayDown
Trap generated when all fans are down and/or when
the fan tray status changes to missing or down
the fan tray status changes to missing or down
.1.3.6.1.4.1.6027.3.1.1.4.0.20
chAlarmFanTrayClear
Trap generated when all fans and/or the fan tray
status changes to operational
status changes to operational
Command Description
hardware watchdog
Enable the hardware watchdog mechanism.
Table 60-4. SNMP Traps and OIDs
OID String
OID Name
Description