DELL S50V User Manual

Page of 1262
E-Series TeraScale Debugging and Diagnostics | 1201
RPM-SFM bring down
If a full set of SFMs are online during the runtime loopback test and a RPM-SFM runtime loopback test 
failure occurs, an automatic SFM walk is launched in an attempt to determine if the failure is due to a 
faulty SFM. If confirmed, the single SFM is identified and disabled (bringdown) by default. 
To disable the automatic bring-down of an SFM that is identified by the SFM walk during the RPM-SFM 
runtime loopback test, use the following CONFIGURATION mode command.
Manual loopback test
This manual dataplane loopback test is a supplemental test to the automatic runtime loopback test and can 
be initiated regardless if the runtime loopback test is enabled or disabled. Use this test to verify that the 
dataplane is actually functional even when a switch fabric status is down but there are at least (max-1) 
SFMs in active or diag failure state. 
Task
Command
Mode
Disable the automatic SFM walk that is 
launched after an RPM-SFM runtime 
loopback test failure.
To re-enable the automatic SFM walk, use 
the 
no dataplane-diag disable 
sfm-walk
 command.
dataplane-diag disable sfm-walk
CONFIGURATION
Note: Disabling the 
sfm-walk
 command prevents the 
sfm-bringdown
 command from taking effect.
Task
Command
Mode
Disable the automatic bring down 
of the single faulty SFM identified 
by the SFM walk during the 
RPM-SFM runtime loopback test.
To re-enable the automatic bring 
down of an SFM, use the 
no 
dataplane-diag disable
 
sfm-bringdown
 command.
dataplane-diag disable sfm-bringdown
CONFIGURATION