DELL S50V User Manual

Page of 1262
E-Series TeraScale Debugging and Diagnostics | 1213
The line card status does not reflect transient errors until FTOS encounters five recoverable or 50 phantom 
transient errors on a card within an hour, as shown in 
type of parity error (transient or real) that occurred. 
Use SNMP to poll the number of transient errors using the objects chSysCardParityPhantomError and 
chSysCardParityRecoverableError. If it has been more than one hour since the last occurrence of the same 
type of error, the counter associated with that type of error is reset to 1.
Figure 61-9.  Viewing the Parity Status of a Line Card
Recognize a non-recoverable parity error
 when it encounters a real transient parity error.
FTOS also generates an SNMP trap, TR_CHM_SRAM_PARITY_NONRECOVERABLE, at the same 
time it generates a console message for non-recoverable parity errors. Use SNMP to poll the number of 
non-recoverable errors using the objects chSysCardParityNonrecovrableError.
Message 12  Console Real Parity Error Message
Apr 29 18:52:50: %RPM0-P:CP %CHMGR-2-CARD_PARITY_ERR: Linecard 6 pp 0 FPC SRAM Hard parity error:  
Address 0x85000004 Index 0x80000
FTOS#show linecard 6
--  Line card 6 --
Status        : online 
Next Boot     : online 
Required Type : E48TF - 48-port 10/100/1000Base-T line card with RJ-45 interfaces (EF)
Current Type  : E48TF - 48-port 10/100/1000Base-T line card with RJ-45 interfaces (EF)
Hardware Rev  : Base  - 1.1  PP0 - 1.0  PP1 - 1.0
Num Ports     : 48 
Up Time       : 3 min, 44 sec
FTOS Version  : 6.5.4.1 
Jumbo Capable : yes 
Boot Flash    : A: 2.3.1.3     B: 2.3.1.3 [booted]
Memory Size   : 268435456 bytes
Temperature   : 42C 
Power Status  : AC 
Voltage       : ok
Serial Number : 0045149      
Part Number   : 7520016602 Rev 06        
Vendor Id     : 04        
Date Code     : 01442005  
Country Code  : 01        
Parity Status : Last Event - FPC DDR Bank [191:128], Transient Failure, Running Count 5
FTOS#show linecard 7 | find “Parity Status”
Parity Status : Last Event - FPC DDR Bank [191:128], Real Failure, Address 0x11ffe00