E-Series TeraScale Debugging and Diagnostics | 1217
Recognize a high CPU condition
appear.
Configure an action upon a hardware error
You can configure FTOS to take an action if it encounters an BTM, FPC, or MAC hardware error.
Buffer traffic manager hardware errors
FTOS displays
, or
In this case, configure an action using the command
hardware monitor linecard asic btm action-on-error
.
You may place the line card in a problem state, reset the card, or shutdown all ports on the card.
Message 14 High CPU Condition
Feb 13 13:56:16: %RPM1-S:CP %CHMGR-5-TASK_CPU_THRESHOLD: Cpu usage above threshold for task
"sysAdmTsk"(100.00%) in CP.
Feb 13 13:56:20: %RPM1-S:CP %CHMGR-5-CPU_THRESHOLD: Overall cp cpu usage above threshold.
Cpu5SecUsage (100)
Feb 13 13:56:20: %RPM1-S:CP %CHMGR-5-TASK_CPU_THRESHOLD_CLR: Cpu usage drops below threshold
for task "sysAdmTsk"(0.00%) in CP.
Message 15 Queue Memory Error
%RPM0-P:CP %CHMGR-1-QMERR_RDBE: (0x30004) Double bit error detected in SRAM pointer memory on
Ingress BTM port-pipe 0 Line card slot 9.
%RPM0-P:CP %CHMGR-1-QMERR_RDBE: (0x30004) Double bit error detected in SRAM pointer memory on
Egress BTM port-pipe 0 Line card slot 9.
Message 16 Buffer Memory Error
RPM0-P:CP %CHMGR-3-BM_STATUS_DBE: Double-bit error detected when reading internal header from
buffer memory on Ingress BTM port-pipe 0 Line card slot 9. Check for temporary or sustained
packet loss with show hardware commands.
%RPM0-P:CP %CHMGR-3-BM_STATUS_DBE: Double-bit error detected when reading internal header
from buffer memory on Egress BTM port-pipe 0 Line card slot 9. Check for temporary or
sustained packet loss with show hardware commands.