Recognize a high CPU condition
 appear.
Configure an action upon a hardware error
You can configure FTOS to take an action if it encounters an BTM, FPC, or MAC hardware error.
Buffer traffic manager hardware errors
FTOS displays 
, or 
In this case, configure an action using the command 
hardware monitor linecard asic btm action-on-error
You may place the line card in a problem state, reset the card, or shutdown all ports on the card.
Message 14  High CPU Condition
Feb 13 13:56:16: %RPM1-S:CP %CHMGR-5-TASK_CPU_THRESHOLD: Cpu usage above threshold for task 
"sysAdmTsk"(100.00%) in CP.
Feb 13 13:56:20: %RPM1-S:CP %CHMGR-5-CPU_THRESHOLD: Overall cp cpu usage above threshold. 
Cpu5SecUsage (100)
Feb 13 13:56:20: %RPM1-S:CP %CHMGR-5-TASK_CPU_THRESHOLD_CLR: Cpu usage drops below threshold 
for task "sysAdmTsk"(0.00%) in CP.
Message 15  Queue Memory Error
%RPM0-P:CP %CHMGR-1-QMERR_RDBE: (0x30004) Double bit error detected in SRAM pointer memory on 
Ingress BTM port-pipe 0 Line card slot 9.
%RPM0-P:CP %CHMGR-1-QMERR_RDBE: (0x30004) Double bit error detected in SRAM pointer memory on 
Egress  BTM port-pipe 0 Line card slot 9.
Message 16  Buffer Memory Error
RPM0-P:CP %CHMGR-3-BM_STATUS_DBE: Double-bit error detected when reading internal header from 
buffer memory on Ingress BTM port-pipe 0 Line card slot 9. Check for temporary or sustained 
packet loss with show hardware commands.
%RPM0-P:CP %CHMGR-3-BM_STATUS_DBE: Double-bit error detected when reading internal header 
from buffer memory on Egress  BTM port-pipe 0 Line card slot 9. Check for temporary or 
sustained packet loss with show hardware commands.