DELL S50V User Manual
1232
|
S-Series Debugging and Diagnostics
www.dell.com | support.dell.com
Figure 62-9. Single Queue Application for S50N with Default Packet Pointers
Troubleshooting packet loss
The
show hardware stack-unit
command, introduced in FTOS 7.7.1.0 is intended primarily to troubleshoot
clear
commands to refresh
those counters, as listed here:
•
show hardware stack-unit cpu data-plane statistics
•
show hardware stack-unit cpu party-bus statistics
•
show hardware stack-unit 0-7 drops unit 0-1 port 0-27
•
show hardware stack-unit 0-7 stack-port 0-52
•
show hardware stack-unit 0-7 unit 0-1 {counters | details | port-stats [detail] | register}
:
•
show hardware {layer2| layer3} acl stack-unit 0-7 stack 0-1
•
show hardware layer3 qos stack-unit 0-7 port-set 0-1
•
show hardware system-flow layer2 stack-unit 0-7 port-set 0-1 [counters]
•
clear hardware stack-unit 0-7 counters
•
clear hardware stack-unit 0-7 unit 0-1 counters
•
clear hardware stack-unit 0-7 cpu data-plane statistics
•
clear hardware stack-unit 0-7 cpu party-bus statistics
•
clear hardware stack-unit 0-7 stack-port 0-52
Displaying Drop Counters
The
show hardware stack-unit 0–7 drops [unit 0–1 [port 0–27]]
command assists in identifying which stack
and
!
buffer-profile fp fsqueue-fp
buffer dedicated queue0 3 queue1 3 queue2 3 queue3 3 queue4 3 queue5 3 queue6 3 queue7 3
buffer dynamic 1256
!
buffer-profile fp fsqueue-hig
buffer dedicated queue0 3 queue1 3 queue2 3 queue3 3 queue4 3 queue5 3 queue6 3 queue7 3
buffer dynamic 1256
!
buffer fp-uplink stack-unit 0 port-set 0 buffer-policy fsqueue-hig
buffer fp-uplink stack-unit 0 port-set 1 buffer-policy fsqueue-hig
!
Interface range gi 0/1 - 48
buffer-policy fsqueue-fp
FTOS#sho run int gi 0/10
!
interface GigabitEthernet 0/10
no ip address