DELL S50V User Manual
![DELL](https://files.manualsbrain.com/attachments/2e2ed634a275b6b98ad69257c58632e179ac1658/common/fit/150/50/0b94a25108df4a3b962d3b8aa65fc4eda1ead8e68832a26b3f5ed6aa6a0b/brand_logo.png)
44
|
Configuration Fundamentals
www.dell.com | support.dell.com
•
find
displays the output of the show command beginning from the first occurrence of specified text
show linecard all
.
Figure 2-11. Filtering Command Outputs with the
find
Command
•
display
displays additional configuration information.
•
no-more
displays the output all at once rather than one screen at a time. This is similar to the command
terminal length
except that the
no-more
option affects the output of the specified command only.
•
save
copies the output to a file for future reference.
Multiple Users in Configuration mode
FTOS notifies all users in the event that there are multiple users logged into CONFIGURATION mode. A
warning message indicates the username, type of connection (console or vty), and in the case of a vty
connection, the IP address of the terminal on which the connection was established. For example:
warning message indicates the username, type of connection (console or vty), and in the case of a vty
connection, the IP address of the terminal on which the connection was established. For example:
•
On the system that telnets into the switch,
appears:
•
On the system that is connected over the console,
If either of these messages appears, Dell Force10 recommends that you coordinate with the users listed in
the message so that you do not unintentionally overwrite each other’s configuration changes.
the message so that you do not unintentionally overwrite each other’s configuration changes.
Note: You can filter a single command output multiple times. The save option should be the last option
entered. For example:
entered. For example:
FTOS# command |
grep
regular-expression |
except
regular-expression
|
grep
other-regular-expression |
find
regular-expression |
save
Message 1 Multiple Users in Configuration mode Telnet Message
% Warning: The following users are currently configuring the system:
User "<username>" on line console0
Message 2 Multiple Users in Configuration mode Telnet Message
% Warning: User "<username>" on line vty0 "10.11.130.2" is in configuration mode
FTOS(conf)#do show linecard all | find 0
0 not present
1 not present
2 online online E48TB E48TB 1-1-463 48
3 not present
4 not present
5 online online E48VB E48VB 1-1-463 48
6 not present