DELL S50V User Manual

Page of 1262
Layer 2 | 581
During an RPM Failover
In the event that an RPM failover occurs, FEFD will become operationally down on all enabled ports for 
approximately 8-10 seconds before automatically becoming operational again.
Figure 25-15.  FEFD state change during an RPM failover
02-05-2009          12:40:38               Local7.Debug     10.16.151.12       
Feb 5 07:06:09:
 
%RPM1-S:CP %RAM-6-FAILOVER_REQ: RPM failover request from active peer: User request.
02-05-2009          12:40:38               Local7.Debug     10.16.151.12       
Feb 5 07:06:19:
 
%RPM1-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Gi 0/45
02-05-2009          12:40:38               Local7.Debug     10.16.151.12       
Feb 5 07:06:19:
 
%RPM1-P:CP %FEFD-5-FEFD-BIDIRECTION-LINK-DETECTED: Interface Gi 0/45 has bidirectional link with its 
peer