DELL S50V User Manual
Port Monitoring | 819
Configuring Port Monitoring
To configure port monitoring:
Display monitor sessions using the command
show monitor session
from EXEC Privilege mode, as shown
.
Figure 38-6. Configuring Port-based Monitoring
, the host and server are exchanging traffic which passes through interface gigabitethernet 1/
1. Interface gigabitethernet 1/1 is the monitored port and gigabitethernet 1/2 is the monitoring port, which
is configured to only monitor traffic received on gigabitethernet 1/1 (host-originated traffic).
is configured to only monitor traffic received on gigabitethernet 1/1 (host-originated traffic).
Step
Command Syntax
Command Mode
Task
1
show interface
EXEC Privilege
Verify that the intended monitoring port has no
configuration other than
configuration other than
no shutdown
, as shown in
.
2
monitor session
CONFIGURATION
Create a monitoring session using the command monitor
session from CONFIGURATION mode, as shown in
session from CONFIGURATION mode, as shown in
.
3
source
MONITOR SESSION
Specify the source and destination port and direction of
traffic, as shown in
traffic, as shown in
.
FTOS(conf-if-gi-1/2)#
show config
!
interface GigabitEthernet 1/2
no ip address
no shutdown
FTOS(conf-if-gi-1/2)#exit
FTOS(conf)#
monitor session 0
FTOS(conf-mon-sess-0)#
source
gig 1/1 dest gig 1/2 direction rx
FTOS(conf-mon-sess-0)#exit
FTOS(conf)#
do show monitor session 0
SessionID Source Destination Direction Mode Type
--------- ------ ----------- --------- ---- ----
0 Gi 1/1 Gi 1/2 rx interface Port-based
FTOS(conf)#