DELL S50V User Manual

Page of 1262
90
|
802.1ag
www.dell.com | support.dell.com
Enable CFM SNMP Traps.
A Trap is sent only when one of the five highest priority defects occur, as shown in 
.
FTOS#show ethernet cfm traceroute-cache
 
Traceroute to 00:01:e8:52:4a:f8 on Domain Customer2, Level 7, MA name Test2 with 
VLAN 2
 
 ------------------------------------------------------------------------------
  Hops              Host              IngressMAC     Ingr Action   Relay Action
                 Next Host            Egress MAC     Egress Action  FWD Status
------------------------------------------------------------------------------
 
   4      00:00:00:01:e8:53:4a:f8   00:01:e8:52:4a:f8  IngOK             RlyHit
          00:00:00:01:e8:52:4a:f8                                        
Terminal MEP
Delete all Link Trace Cache entries.
clear ethernet cfm traceroute-cache
EXEC Privilege
Task
Command Syntax
Command Mode
Enable SNMP trap messages for 
Ethernet CFM.
snmp-server enable traps ecfm
CONFIGURATION
Table 5-2.  ECFM SNMP Traps
Cross-connect defect
%ECFM-5-ECFM_XCON_ALARM: Cross connect fault detected by MEP 1 in Domain customer1 
at Level 7 VLAN 1000
Error-CCM defect
%ECFM-5-ECFM_ERROR_ALARM: Error CCM Defect detected by MEP 1 in Domain customer1 
at Level 7 VLAN 1000
MAC Status defect
%ECFM-5-ECFM_MAC_STATUS_ALARM: MAC Status Defect detected by MEP 1 in Domain 
provider at Level 4 VLAN 3000
Remote CCM defect
%ECFM-5-ECFM_REMOTE_ALARM: Remote CCM Defect detected by MEP 3 in Domain customer1 
at Level 7 VLAN 1000
RDI defect
%ECFM-5-ECFM_RDI_ALARM: RDI Defect detected by MEP 3 in Domain customer1 at Level 
7 VLAN 1000
Task
Command Syntax
Command Mode