DELL S50V User Manual
![DELL](https://files.manualsbrain.com/attachments/2e2ed634a275b6b98ad69257c58632e179ac1658/common/fit/150/50/0b94a25108df4a3b962d3b8aa65fc4eda1ead8e68832a26b3f5ed6aa6a0b/brand_logo.png)
954
|
Service Provider Bridging
www.dell.com | support.dell.com
Display the VLAN-Stacking configuration for a switchport using the command
show config
from
INTERFACE mode, as shown in
Figure 46-3. Displaying the VLAN-Stack Configuration on a Layer 2 Port
Enable VLAN-Stacking for a VLAN
To enable VLAN-Stacking for a VLAN:
Display the status and members of a VLAN using the
show vlan
command from EXEC Privilege mode.
Members of a VLAN-Stacking-enabled VLAN are marked with an M in column Q.
Figure 46-4. Display the Members of a VLAN-Stacking-enabled VLAN
Configure the Protocol Type Value for the Outer VLAN Tag
The Tag Protocol Identifier (TPID) field of the S-Tag is user-configurable:
Display the S-Tag TPID for a VLAN using the command
show running-config
from EXEC privilege
mode. FTOS displays the S-Tag TPID only if it is a non-default value.
Task
Command Syntax
Command Mode
Enable VLAN-Stacking for the VLAN.
INTERFACE VLAN
vlan-stack compatible
Task
Command Syntax
Command Mode
Select a value for the S-Tag TPID.
Default: 9100
CONFIGURATION
vlan-stack protocol-type
FTOS#show run interface gi 7/0
!
interface GigabitEthernet 7/0
no ip address
switchport
vlan-stack access
no shutdown
FTOS#show run interface gi 7/12
!
interface GigabitEthernet 7/12
no ip address
switchport
vlan-stack trunk
no shutdown
FTOS#show vlan
Codes: * - Default VLAN, G - GVRP VLANs
NUM Status Q Ports
* 1 Active U Gi 13/0-5,18
2 Inactive
3 Inactive