Service Provider Bridging | 959
Figure 46-8.  First-byte TPID Match on the E-Series ExaScale
 details the outcome of matched and mis-matched TPIDs in a VLAN-stacking network with the 
E-Series.
VLAN Stacking with C-Series and S-Series
The default TPID for the outer VLAN tag is 0x9100. Beginning with FTOS version 8.2.1.0, both the 
C-Series and S-Series allow you to configure both bytes of the 2-byte TPID. Previous versions allowed 
you to configure the first byte only, and thus, the systems did not differentiate between TPIDs with a 
common first byte. For example 0x8100 and any other TPID beginning with 0x81 were treated as the same 
TPID, as shown in 
. Versions 8.2.1.0 and later differentiate between 0x9100 and 0x91XY, as 
shown in 
Table 46-1.  E-Series Behaviors for Mis-matched TPID
Network
Position
Incoming
Packet TPID
System
TPID
Match Type
TeraScale Behavior
ExaScale Behavior
Core
0xUVWX
0xUVYZ
1st-byte match
switch as 0xUVYZ
drop
0xUVWZ
0xQRST
mismatch
drop
drop
Egress Access 
Point
0xUVWX
0xUVYZ
1st-byte match
switch as 0xUVYZ
drop
0x81WX
0x81YZ
1st-byte match
switch as is (no 
decapsulation)
drop
0xUVWZ
0xQRST
mismatch
drop
drop