DELL S50V User Manual
![DELL](https://files.manualsbrain.com/attachments/2e2ed634a275b6b98ad69257c58632e179ac1658/common/fit/150/50/0b94a25108df4a3b962d3b8aa65fc4eda1ead8e68832a26b3f5ed6aa6a0b/brand_logo.png)
sFlow | 977
Figure 47-3. Command Example:
show sflow interface
Figure 47-4. Command Example:
show running-config interface
Show sFlow on a Line Card
Use the following command to view sFlow statistitics on a specified line card:
show sflow linecard
command:
Figure 47-5. Command Example:
show sflow linecard
Command Syntax
Command Mode
Purpose
show sflow linecard slot-number
EXEC
Display sFlow configuration information and statistics on
the specified interface.
the specified interface.
FTOS#show sflow interface gigabitethernet 1/16
Gi 1/16
Configured sampling rate :8192
Actual sampling rate :8192
Sub-sampling rate :2
Counter polling interval :15
Samples rcvd from h/w :33
Samples dropped for sub-sampling :6
FTOS#show running-config interface gigabitethernet 1/16
!
interface GigabitEthernet 1/16
no ip address
mtu 9252
ip mtu 9234
switchport
sflow enable
sflow sample-rate 8192
no shutdown
FTOS#show sflow linecard 1
Linecard 1
Samples rcvd from h/w :165
Samples dropped for sub-sampling :69
Total UDP packets exported :77
UDP packets exported via RPM :77
UDP packets dropped :