DELL 6024 User Manual

Page of 474
170
Configuring System Information
www
.dell.com | support.dell.com
Performing Fiber Optic Cable Tests Using CLI Commands
The following table contains the CLI command for performing fiber optic cable tests.
The following is an example of the CLI command: 
console# show fiber-ports optical-transceiver
The following columns appear on the screen: 
Temp — Internally measured transceiver temperature
Voltage — Internally measured supply voltage
Current — Measured TX bias current
Output Power — Measured TX output power in milliWatts
Input Power — Measured RX received power in milliwatts
TX Fault — Transmitter fault
 
NOTE: 
Finisar transceivers do not support the transmitter fault diagnostic testing.
LOS — Loss of signal
Data Ready — Indicates transceiver has archived power up and data is ready
N/A — Not Available, N/S - Not Supported, W - Warning, E - Error
 
NOTE: 
Fiber Optic analysis feature works only on SFPs that support the digital diagnostic standard SFF-
4872.
Managing Device Security
Use the Management Security page to set management security parameters for port, user, and 
server security. 
To open the Management Security page, click System
→ Management Security in the tree view. 
Defining Access Profiles
Use the Access Profiles page to define profiles and rules for accessing the device. You can limit 
access to management functions to user groups, which are defined by ingress interfaces and source 
IP address and/or source IP subnets. 
Table 6-29.
Fiber Optic Cable Test CLI Command
CLI Command
Description
show fiber-ports optical-
transceiver [
interface
[
detailed
]
Displays the optical transceiver 
diagnostics.