• If a BPDU is received from a remote device, BPDU guard places the port in an 
Err-Disabled Blocking state and no traffic is forwarded on the port.
• If no BPDU is received from a remote device, loop guard places the port in a 
Loop-Inconsistent Blocking state and no traffic is forwarded on the port.
Example
Dell(conf)#interface tengigabitethernet 4/1
Dell(conf-if-gi-4/0)#spanning-tree rstp edge-port
Dell(conf-if-gi-4/0)#show config
!
interface TenGigabitEthernet 4/1
  no ip address
  switchport
  spanning-tree rstp edge-port
  no shutdown
Dell#
tc-flush-standard
Enable the MAC address flushing after receiving every topology change notification.
Syntax
tc-flush-standard
To disable, use the no tc-flush-standard command.
Defaults
Disabled
Command 
Modes
CONFIGURATION (conf-rstp)
Command 
History
This guide is platform-specific. For command information about other platforms, 
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version
Description
9.7(0.0)
Introduced on the S6000-ON.
9.0.2.0
Introduced on the S6000.
8.3.19.0
Introduced on the S4820T.
8.3.11.1
Introduced on the Z9000.
8.3.7.0
Introduced on the S4810.
7.6.1.0
Introduced on the S-Series.
7.5.1.0
Introduced on the C-Series.
6.5.1.0
Introduced on the E-Series.
Rapid Spanning Tree Protocol (RSTP)