DELL 9.8(0.0) User Manual
• If a BPDU is received from a remote device, BPDU guard places the port in an
Err-Disabled Blocking state and no traffic is forwarded on the port.
• If no BPDU is received from a remote device, loop guard places the port in a
Loop-Inconsistent Blocking state and no traffic is forwarded on the port.
Example
Dell(conf)#interface tengigabitethernet 4/1
Dell(conf-if-gi-4/0)#spanning-tree rstp edge-port
Dell(conf-if-gi-4/0)#show config
!
interface TenGigabitEthernet 4/1
no ip address
switchport
spanning-tree rstp edge-port
no shutdown
Dell#
tc-flush-standard
Enable the MAC address flushing after receiving every topology change notification.
Syntax
tc-flush-standard
To disable, use the no tc-flush-standard command.
To disable, use the no tc-flush-standard command.
Defaults
Disabled
Command
Modes
Modes
CONFIGURATION (conf-rstp)
Command
History
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version
Description
9.7(0.0)
Introduced on the S6000-ON.
9.0.2.0
Introduced on the S6000.
8.3.19.0
Introduced on the S4820T.
8.3.11.1
Introduced on the Z9000.
8.3.7.0
Introduced on the S4810.
7.6.1.0
Introduced on the S-Series.
7.5.1.0
Introduced on the C-Series.
6.5.1.0
Introduced on the E-Series.
Rapid Spanning Tree Protocol (RSTP)
1571