seq arp (for Extended MAC ACLs)
Configure an egress filter with a sequence number that filters ARP packets meeting this criteria. This 
command is supported only on 12-port GE line cards with SFP optics. For specifications, refer to your line 
card documentation.
NOTE: Only the options that have been newly introduced in Release 9.3(0.0) and Release 9.4(0.0) 
are described here. For a complete description on all of the keywords and variables that are 
available with this command, refer the topic of this command discussed earlier in this guide.
Syntax
seq sequence-number {deny | permit} arp {destination-mac-
address mac-address-mask
 | any} vlan vlan-id {ip-address | any 
| opcode code-number} [count [byte]] [order] [log [interval 
minutes] [threshold-in-msgs [count]] [monitor]
To remove this filter, use the no seq sequence-number command.
Parameters
log
(OPTIONAL) Enter the keyword log to enable the triggering 
of ACL log messages.
threshold-in 
msgs count
(OPTIONAL) Enter the threshold-in-msgs keyword 
followed by a value to indicate the maximum number of ACL 
logs that can be generated, exceeding which the generation 
of ACL logs is terminated. with the seq, permit, or deny 
commands. You can enter a threshold in the range of 1-100.
interval 
minutes
(OPTIONAL) Enter the keyword interval followed by the 
time period in minutes at which ACL logs must be generated. 
You can enter an interval in the range of 1-10 minutes.
monitor
(OPTIONAL) Enter the keyword monitor when the rule is 
describing the traffic that you want to monitor and the ACL 
in which you are creating the rule is applied to the monitored 
interface.
Defaults
By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
The default frequency at which ACL logs are generated is 5 minutes. By default, 
flow-based monitoring is not enabled.
Command 
Modes
CONFIGURATION-EXTENDED-ACCESS-LIST
Command 
History
Version
Description
9.7(0.0)
Introduced on the S6000–ON.
9.4(0.0)
Added support for flow-based monitoring on the S4810, 
S4820T, S6000, Z9000, and MXL 10/40GbE Switch IO 
Module platforms.
Access Control Lists (ACL)
353