  Chapter 3: Using the Console Port
212779-A, December 2001
n
Units in a closed or multi-unit rack assembly may have an operating ambient temperature 
higher than the ambient temperature of the room. The ambient temperature of an operating 
switch must not exceed 40
o
C. If the operating ambient temperature cannot be lowered 
before this maximum is reached, turn off the switch and let it cool.
n
It may be necessary to cool the room to a lower temperature or provide a fan for greater air 
circulation. Resolve the room’s cooling and circulation problems before turning the switch 
back on.
Switch Will Not Boot
Symptoms 
All the Alteon switch LEDs stay on, and the command prompt does not appear on the console.
Cause 
The operating system may have been damaged.
Actions
Perform a serial upgrade of the Web switch software. See 
Switch Will Not Accept TFTP Software Upgrade
Symptoms 
The unit is unable to contact the TFTP server and download files. 
Cause 
There may be due a problem with the TFTP server, or the Web switch software may be dam-
aged.
Actions
If the software was damaged, perform a serial upgrade of the switch software. See 
.