Chapter 8: Device Management 
 
 
171
 
 
Note: If either of these checkboxes is selected and power input is not 
actually connected, the power LED at the front of the unit turns red. 
 
To turn off the automatic detection: 
  Deselect the checkbox for the appropriate power supply. 
 
To reset to factory defaults: 
 
Click Reset To Defaults. 
Note: The KX II does NOT report power supply status to 
CommandCenter. Dominion I (generation 1), however, does report 
power supply status to CommandCenter. 
 
Configuring Ports 
The Port Configuration page displays a list of the KX II ports.   
Ports connected to KVM target servers (blades and standard servers) 
and rack PDUs (power strips) are displayed in blue, and can be edited.   
Ports with no CIM connected or with a blank CIM name, a default port 
name of Dominion-KX2_Port#is assigned, where Port# is the number of 
the KX II physical port.     
When a port's status is down, Not Available is displayed as its status. A 
port may be down when the port's CIM is removed or powered down.     
Note: For blade chassis, the blade chassis name can be changed but its 
blade slot names cannot be changed.   
After you have renamed the port, use the Reset to Default function at 
any time to return it to its default port name.   
When you reset a port name to its default, any existing power 
associations are removed and, if the port is a part of a port group, it is 
removed from the group. 
 
To access a port configuration: 
1.  Choose Device Settings > Port Configuration. The Port Configuration 
Page opens. 
This page is initially displayed in port number order, but can be 
sorted on any of the fields by clicking on the column heading. 
  Port Number - Numbered from 1 to the total number of ports 
available for the KX II device   
  Port Name - The name assigned to the port