Configuring KX II Local Port Settings 
From the Local Port Settings page, you can customize many settings for 
the KX II Local Console including keyboard, hot keys, video switching 
delay, power save mode, local user interface resolution settings, and 
local user authentication. Further, you can change a USB profile from the 
local port. 
For the KX2-808, KX2-832 and KX2-864, you are also able to configure 
the extended local port from the Local Port Settings page. The extended 
local port may be connected to a Paragon switch or User Station to 
extend the reach of the Local port. Like the standard local port, you are 
able to configure keyboard, hot keys, video switching delay, power save 
mode, local user interface resolution settings, and local user 
authentication settings. The extended local port can be configured from 
both the Remote Console and the Local Console. See 
KX2-808, 
KX2-832 and KX2-864 Standard and Extended Local Port Settings
 
(on page 210) for more information on the standard local port and 
extended local port. 
Note: If the extended local port is enabled on the KX2-808, KX2-832 and 
KX2-864 and nothing is connected to the port, you will experience a 
delay of 2-3 seconds when switching to a target via the local port. 
Note: Some changes you make to the settings on the Local Port Settings 
page restart the browser you are working in. If a browser restart occurs 
when a setting is changed, it is noted in the steps provided here. 
 
To configure the local port settings: 
1.  Choose Device Settings > Local Port Settings. The Local Port 
Settings page opens. 
2.  Select the checkbox next to the Enable Standard Local Port to 
enable it. Deselect the checkbox to disable it. By default, the 
standard local port is enabled but can be disabled as needed. The 
browser will be restarted when this change is made. If you are using 
the tiering feature, this feature will be turned off since both features 
cannot be used at the same time.   
3.  If you are using a KX2-808, KX2-832 or KX2-864 device, select the 
checkbox next to the Extended Local Port to enable it. Deselect the 
checkbox(s) to disable it. If you are using the smart card feature, the 
extended local port be must be disabled. The browser will be 
restarted when this change is made. 
If both the standard local port and extended local port are disabled, 
the local ports cannot be accessed. If you attempt to access a 
KX2-808, KX2-832 or KX2-864 through a disabled local port, a 
message will be displayed indicating that the device is under remote 
management and that the login is disabled.