Raritan Computer DKX2-v2.6.0-0R-E User Manual

Page of 408
 
Chapter 12: Command Line Interface (CLI) 
 
 
261
 
 
Initial Configuration Using CLI 
Note: These steps, which use the CLI, are optional since the same 
configuration can be done via KVM. See 
Getting Started
 (on page 12) 
for more information. 
KX II devices come from the factory with default factory settings. When 
you first power up and connect to the device, you must set the following 
basic parameters so the device can be accessed securely from the 
network: 
1.  Reset the administrator password. All KX II devices are shipped with 
the same default password. Therefore, to avoid security breaches it 
is imperative that you change the admin password from raritan to 
one customized for the administrators who will manage the KX II 
device. 
2.  Assign the IP address, subnet mask, and gateway IP address to 
allow remote access. 
 
Setting Parameters 
To set parameters, you must be logged on with administrative privileges. 
At the top level, you will see the "Username" > prompt, which for the 
initial configuration is "admin". Enter the top command to return to the 
top menu level. 
Note: If you have logged on with a different user name, that user name 
will appear instead of admin.   
 
Setting Network Parameters 
Network parameters are configured using the interface command. 
admin > Config > Network > interface ipauto none ip 
192.168.151.12 mask 255.255.255.0 gw 192.168.151.1 mode 
auto 
When the command is accepted, the device automatically drops the 
connection. You must reconnect to the device using the new IP address 
and the user name and password you created in the resetting factory 
default password section. 
Important: If the password is forgotten, the KX II will need to be 
reset to the factory default from the Reset button on the back of the 
KX II. The initial configuration tasks will need to be performed again 
if this is done.