Raritan Computer DKX132 User Manual

Page of 106
A
PPENDIX 
C:
 
FAQ
S
 
93 
 
 
 
Manageability 
Q
UESTION
 
A
NSWER
 
Can Dominion KX be 
remotely managed and 
configured via web 
browser? 
 
Yes. Dominion KX can be completely configured remotely via Web 
browser. Note that this does require that your workstation have Java 
Runtime Environment 1.4.2 installed. 
Besides the initial setting of Dominion KX’s IP address, everything 
about the solution can be completely set up over the network. (In fact, 
using a crossover Ethernet cable and Dominion KX’s default IP 
address, you can even configure even the initial settings configured via 
Web browser.) 
Can I backup and restore 
Dominion KX’s 
configuration? 
 
Yes, Dominion KX’s device and user configurations can be completely 
backed up for later restoration in the event of a catastrophe. More 
commonly, this functionality is also very useful for configuring 
multiple Dominion KX units if you have not deployed Raritan’s CC-SG 
centralized management appliance. You can back up the user 
configuration and restore it on remaining units. 
Dominion KX’s backup and restore functionality can be utilized 
remotely over the network; in fact, via a Web browser. 
What auditing or 
logging does Dominion 
KX offer? 
For complete accountability, Dominion KX logs all major user events 
with a date and time stamp. For instance, reported events include (but 
are not limited to): user login, user logout, user access of a particular 
server, unsuccessful login, configuration changes, etc 
Can Dominion KX 
integrate with syslog? 
Yes, for your convenience, in addition to Dominion KX’s own internal 
logging capabilities, Dominion KX can also send the following logged 
events to a centralized syslog server: 
•  Network 
•  Admin 
•  Error 
•  Text 
•  System 
Can Dominion KX’s 
internal clock be 
synchronized with a 
timeserver? 
Yes, Dominion KX supports the industry-standard NTP protocol for 
synchronization with either your corporate timeserver, or with any 
public time server [assuming that outbound NTP requests are allowed 
through your corporate firewall]. 
Does the power supply 
used by Dominion KX 
automatically detect 
voltage settings? 
Yes, Dominion KX’s power supply can be used in any AC voltage 
ranges from 100-240 volts, at 50-60 Hz.