Nortech Systems RS-422/485 User Manual

Page of 156
Appendix A - sDIO Module
100
Adept SmartController User’s Guide, Rev. E 
3. Select option 2.
2 - Edit system configuration
Then, press ENTER to continue.
4. Select either option 5 or option 6:
5 - Change DIGITAL_INPUT configuration
or
6 - Change DIGITAL_OUTPUT configuration
Then, press ENTER to continue.
5. The program will step you through the process of adding a new statement to 
assign the appropriate I/O signals to a block, and then to a byte (1 to 4) within a 
block. With the sDIO, the first 8 input channels are mapped to byte 1, the second 8 
input channels to byte 2, and so on. See 
. Using 
this process, you must assign groups of signal numbers to bytes 1 to 4 for each 
block. See the 
 for the input settings of a system 
with two sDIO modules. When you are done editing the I/O choose not to add a 
new statement.
6. Save the changes, if you are satisfied with your choices.
7. Continue to select 0 to return through the higher menus. Select 0 once more to exit 
to the system monitor.
8. Disconnect your AdeptWindowsPC or serial communication session to the 
SmartController.
9. Cycle the 24VDC input power to the sDIO.
10. Cycle the 24VDC input power to the SmartController.
11. Reconnect your AdeptWindowsPC or serial communication session to the 
SmartController.