National Instruments NI CVS-1450 Series User Manual

Page of 91
Chapter 4
Digital I/O Functionality
© National Instruments Corporation
4-9
An example of using general-purpose outputs is driving a relay that turns 
on an Inspection in Progress light for an operator to see while the inspection 
sequence is running.
I/O for Fault Conditions
The CVS-1450 device recognizes the following fault conditions:
External shutdown, when Shutdown mode is enabled
Watchdog timer expiration
Overheat
The behavior of the CVS-1450 device in the event of a fault condition is 
dependent on configuration settings of the SAFE MODE DIP switch and 
the software-enabled Shutdown mode. Table 4-4 summarizes how user 
configuration affects the behavior of the CVS-1450 device in the event of a 
fault condition. To resume operation, address the fault condition and reset 
the CVS-1450 device. The following sections describe each fault condition.
Table 4-4.  Configuration Settings and Effects
Fault 
Condition
Configuration Settings
Configuration Effects
Safe Mode 
DIP
Shutdown 
Enabled
Processing Halts
Outputs Change to 
User-Defined States
External 
Shutdown 
On
N/A
N/A
No
Off
On
Yes
Yes
Off
Off
No
No
Watchdog
On
N/A
N/A
No
Off
On
Yes
Yes
Off
Off
Yes
No
Overheat
On
N/A
Yes
No
Off
On
Yes
Yes
Off
Off
Yes
No