Netgear ReadyNAS 2120 User Manual
Maintenance
42
NETGEAR ReadyNAS OS 6 Rack-Mount Storage Systems
4.
Lift the top cover from the chassis.
You now have full access to the inside of the system.
Replace a Fan
If a fan fails, the remaining fans ramp up to full speed, the Error LED on the control panel
lights, and an email alert is sent to the system administrator. Replace a failed fan as soon as
possible. Remove the top chassis cover while the system is still running to determine which
fan failed.
lights, and an email alert is sent to the system administrator. Replace a failed fan as soon as
possible. Remove the top chassis cover while the system is still running to determine which
fan failed.
Fans are hot-pluggable, so you do not need to power down your system when replacing a
fan.
fan.
To replace a fan on a 2120:
1.
Remove the chassis cover.
2.
Disconnect the fan’s power connections.