Clear Counters 
Command Name 
port clear counters  
Description  
Clears all the numbers in the counters for a given port.  These are counters 
for RX bytes and TX bytes and so on. 
Syntax 
port clear counters <port-no> 
Parameters  
port-no 
port number (1 ~ 14) 
Examples 
N-TRON/Admin#[1]> port clear counters 6 
Counters of Port[6] are : [cleared]
 
NOTES 
This will clear all data in the port specific counters.  This data cannot be 
recovered after this step. 
 
Clear Intruder Log 
Command Name 
port clear intruderlog  
Description  
This command will clear all intruders out of the intruder log. 
Syntax 
port clear intruderlog 
Parameters  
None 
Examples 
N-TRON/Admin#[1]> port clear intruderlog 
NOTES 
This will clear all data from the intruder log.  This data can not be 
recovered after this step. 
 
 
 
Trunk related commands 
 
Enable or disableTrunking
 
Command Name 
trunk set <enable | disable> 
Description  
To enable or disable the trunk that is already created.   
Syntax 
trunk set enable  
trunk set disable  
Parameters  
Enable | disable 
Examples 
N-TRON/Admin#[1]> trunk set enable 
Trunking is activated. 
N-TRON/Admin#[1]> trunk set disable  
Trunking is deactivated. 
NOTES 
RSTP must be disabled in order to use Trunking.  All trunk ports must be at 
the same speed and duplex mode.  It is best to hard code speed and duplex 
mode for each trunking link, at both ends. 
Do not use Trunking on a switch that is directly in an active N-Ring. 
 
Modify Trunk 
Command Name 
trunk modify 
Description  
To add new required ports to the trunk in order to withstand high traffic. 
Syntax 
trunk modify  <port-list> [-name <trunk-name>] 
Parameters  
port-list 
          Port numbers to be in the trunk.   
trunk-name 
          Name given to a trunk  
Examples 
N-TRON/Admin#[6]trunk> modify 1,2 -name trunk1 
NOTES 
A  maximum  of  4  ports  can  be  in  a  trunk.  All  trunk  ports  must  be  at  the 
same  speed  and  duplex  mode.  If  a  port  is  not  linked,  there  could  be 
difficulty matching similar speed and duplex mode. It is best to hard code 
speed and duplex mode for each trunking link, at both ends.