Nortech Systems XUSR User Manual

Page of 156
Appendix B - Adept DeviceNet
122
Adept SmartController User’s Guide, Rev. E 
Figure B-5. Example of a Terminating Resistor Installation on a DeviceNet Bus
Power Supply and the DeviceNet Bus
The DeviceNet network allows distribution of power supplies on the network cable 
system. Follow these general rules to achieve a safe and reliable operation:
• Use power supplies rated at 24V
• Minimize installation problems by using one power supply with sufficient 
current to operate all the attached nodes. This must comply with the national 
and international safety standards.
• Make sure that each power supply incorporates current limit protection.
• Make sure each power supply is temperature compensated.
• Provide over current protection for each segment of your DeviceNet cable 
installation.
NOTE: Adept does not supply the 24V operating voltage for the 
DeviceNet bus on the SmartController or any other Adept component.
Power Capabilities of a DeviceNet Cable System
A DeviceNet cable system has several power rating constraints. The cable type and the 
length of the cable specify the maximum current on a cable. Thick and thin cable have:
• 24 VDC power rating
• Optional power-supply tabs
If the power supplies are equipped with Schottky diodes, the optional power supply tabs 
must be protected from bus back-feeding of current among the power supplies on the bus. 
We also recommended the use of fuse protection for every trunkline in the cable system.
WARNING: 
The DeviceNet specification requires that the 
CAN_H and CAN_L signal lines tolerate voltages up to 
18V. Since the supply voltage exceeds 18V, improperly 
wiring the supply voltage to these signal lines may cause 
permanent damage.
Pin 4
Pin 5
Terminating 
Resistor