28
C
HAPTER
 2: I
NSTALLATION
 
AND
 S
ETUP
Stacking the Switch
and Other Devices
Up to four units can be placed on top of one another. If mixing 
SuperStack II devices, the smaller units must be positioned at the top 
using rubber pads.
This section relates only to physically placing the devices on top of each 
other. The switch cannot be used to form a logical stack. It cannot be 
linked to other switches using special expansion cables to form a larger 
switch.
Apply the pads to the underside of the device by sticking a pad in the 
marked area at each corner of the switch. Place the devices on top of 
each other, ensuring that the pads of the upper device line up with the 
recesses of the lower device.
Connecting 
Equipment to the 
Console Port
Connection to the console port is used for direct local management. The 
Switch 9100 console port settings are set as follows:
Baud rate — 9600
Data bits — 8
Stop bit — 1
Parity — None
Flow control — XON/XOFF
The terminal connected to the console port on the switch must be 
configured with the same settings. This procedure will be described in the 
documentation supplied with the terminal.
Appropriate cables are available from your local supplier. To make your 
own cables, pinouts for a DB-9 male console connector are described in 
.
Table 6   Console Connector Pinouts
Function
Pin Number
Direction
DCD (data carrier detect)
1
In
RXD (receive data)
2
In
TXD (transmit data)
3
Out
DTR (data terminal ready)
4
Out
(continued)