3com 8810 User Manual

Page of 97
90
C
HAPTER
 6: S
WITCH
 M
ONITORING
 
AND
 M
AINTENANCE
Step 6: After you provide the required information, the system accesses the 
Ethernet interface submenu again:
ETHERNET  SUBMENU
 
1. Download file to SDRAM through ethernet interface and boot
 
2. Download file to Flash through ethernet interface
 
3. Download file to HardDisk through ethernet interface
 
4. Modify ethernet interface boot parameter
 
0. Return to main menu
 
Enter your choice(0-4): 2 
Step 7: At the prompt displayed in the last step, select a place for retaining the 
downloaded file (the Flash for example by entering 2), press Enter, and the system 
will display the following information in the terminal:
Attached TCP/IP interface to fei0.
 
Attaching network interface lo0... done.
 
boot device          : fei0
 
unit number          : 0
 
processor number     : 0
 
host name            : 8500
 
file name            : 8500.app
 
inet on ethernet (e) : 1.1.1.1
 
host inet (h)        : 1.1.1.2
 
flags (f)            : 0x80
 
Prepare for loading....OK
 
Loading......done
 
flash:/s8500.app already exist,
 
delete it?(Y/N):y
 
Deleting file------------------------------------------------------
 
-------------------------------------------------Done
 
Free flash Space : 15862784 bytes
 
Writing Flash------------------------------------------------------
 
--------------------------------------------------------------------
--------------------------------------------------Done 
Step 8: The information displayed in the last step means a successful file 
downloading operation. In this case, the system accesses the Ethernet interface 
submenu again and the user can make selection as needed. The details will not be 
covered here.
ETHERNET  SUBMENU
 
1. Download file to SDRAM through ethernet interface and boot
 
2. Download file to Flash through ethernet interface
 
3. Download file to HardDisk through ethernet interface
 
4. Modify ethernet interface boot parameter
 
0. Return to main menu
 
Enter your choice(0-4): 
Upgrading software through management Ethernet port (FTP)
Introduction to FTP
The Switch 8800 Family applications can also be updated through the Ethernet 
port and using FTP.
Following is the upgrading procedure, using the Switch 8814 working as an FTP 
Client as an example.
Upgrade procedure