3com 3C16980 User Manual

Page of 62
24
C
HAPTER
 2: I
NSTALLING
 
THE
 S
WITCH
Choosing a Suitable 
Site
The Switch is suited for use in an office environment where it can be 
mounted in a standard 19-inch equipment rack, or free standing. 
Alternatively, the Switch can be rack-mounted in a wiring closet or 
equipment room. A rack-mounting kit, containing two mounting 
brackets and six screws, is supplied with the Switch.
When deciding where to position the Switch, ensure that:
You are able to meet the configuration rules detailed in 
.
The Switch is accessible and cables can be connected easily.
Cabling is away from:
Sources of electrical noise such as radios, transmitters and 
broadband amplifiers
Power lines and fluorescent lighting fixtures
Water or moisture cannot enter the case of the Switch.
Air-flow is not restricted around the Switch or through the vents in the 
side of the Switch. We recommend that you provide a minimum of 
25mm (1in.) clearance.
No more than four Switch units are placed on top of one another, if 
the units are free standing.
Rack-mounting
The Switch is 1.5U high and fits in most standard 19-inch racks.
CAUTION: Disconnect all cables from the Switch before continuing. 
Remove all self adhesive pads from the underside of the Switch if they 
have been fitted.
Place the Switch the right way up on a hard flat surface, with the front 
facing towards you.
Locate a mounting bracket over the mounting holes on one side of the 
Switch, as shown in 
.
16980ua.bk  Page 24  Friday, April 30, 1999  9:03 AM