3com 3C16894 4-slot Chassis User Manual

Page of 80
12
C
HAPTER
 1: S
WITCH
 7750 C
OMPONENTS
Module LEDs 
The module LEDs show the status of the I/O modules, as described in Table 9.
Power LEDs 
PWR1, PWR2, and PWR3 LEDs show the status of the power modules, as 
described in Table 10.
Fan LED
Fan LEDs show the status of the fan frame, as described in Table 11.
Reset Button
The reset button resets the entire system. 
Fabric 32 Submodules
The Fabric 32 provides a slot for one submodule. The Fabric 32 supports the 
following submodules:
4-Port 1000BASE-X-GBIC 
Submodule
The 4-port 1000BASE-X-GBIC submodule provides four GE full-duplex Ethernet 
GBIC ports. 
Figure 4 illustrates the 4-port 1000BASE-X-GBIC submodule.
ACTIVE
Green — No data is being transmitted or received.
 
Green flashing — Data is being transmitted or received. 
Table 8   Ethernet Port LEDs (continued)
LED
Description
Table 9   I/O Module LEDs 
LED
Status description
RUN
Green or off — The module failed or has not been inserted.
 
Green flashing — The module is working normally.
ALM
Off — The module is working normally or has not been 
inserted.
 
Green or green flashing — The module failed or is not 
working normally.
Table 10   Power LEDs 
LED
Description
OK
Green — The corresponding power module is working 
normally. 
 
Off — The corresponding power module is not working or 
has not been installed.
FAIL
Green — The corresponding power module is not working.
 
Off — The corresponding power module works normally or 
has not been installed.
Table 11   Fan LEDs 
LED
Description
OK
Green — The fan is working normally. 
 
Off — The fan is not working or has not been installed. 
FAIL
Green — The fan is not working.
 
Off — The fan is working normally or has not been installed.