3com 3C16987A User Manual

Page of 62
Configuration Rules with Full Duplex
21
The key topology rules are:
Maximum UTP cable length is 100m (328ft) over Category 5 cable.
A 412m (1352ft) fiber run is allowed for connecting switch-to-switch, 
or endstation-to-switch, using half-duplex 100BASE-FX.
A total network span of 325m (1066ft) is allowed in single-repeater 
topologies (one hub stack per wiring closet with a fiber run to the 
collapsed backbone). For example, a 225m (738ft) fiber link from a 
repeater to a router or switch, plus a 100m (328ft) UTP link from a 
repeater out to the endstations.
Configuration Rules 
with Full Duplex
The Switch provides full duplex support for all its ports. Full duplex allows 
packets to be transmitted and received simultaneously and, in effect, 
doubles the potential throughput of a link.
With full duplex, the Ethernet topology rules are the same, but the Fast 
Ethernet rules are:
Maximum UTP cable length is 100m (328ft) over Category 5 cable.
A 2km (6562ft) fiber link is allowed for connecting switch-to-switch, 
or endstation-to-switch.