3com 3C16895 User Manual

Page of 74
34
C
HAPTER
 2: I
NSTALLING
 T
HE
 S
WITCH
 7750
During the installation, wear an antistatic wrist strap and antistatic gloves. See 
“Static Electricity” on page 35 for additional information on preventing static.
WARNING: Follow local safety regulations when performing any operation with 
the Switch 7750. Follow the related safety information and special safety 
instructions provided by 3Com. 3Com bears no responsibility for accidents that 
occur due to violations of safe operation requirements. 
Electrical Safety
To maintain electrical safety, note the following recommendations:
Look carefully for possible hazards in your work area, such as ungrounded 
power extension cables, missing safety grounds, and moist floors.
Locate the emergency power-off switch in the room where you are working. 
Shut the power off at once in the event of an accident.
Unplug all the power cords and external cables before moving the chassis.
Never assume that power is disconnected from a circuit. Always check.
Moving the Switch
Use caution when moving the Switch 7750. Note the following recommendations 
when moving the switch:
Do not move the switch alone. Work with another person. 
Move the switch slowly. Never move suddenly or twist your body. 
Always disconnect all external cables (including power cord) before lifting or 
moving the chassis.
Do not hold the power handles when carrying the switch. 
Do not put fingers into the vent of the chassis when carrying the switch.
Since the power handles and vent have not been designed to bear the weight 
of the entire chassis, using them to carry the switch may damage the switch or 
even injure personnel.
Laser Safety
Some I/O modules on the Switch 7750 have optical ports. Make sure that an 
optical connector is connected to the optical ports, or a dust proof cover is fitted, 
as invisible laser radiation can be emitted from the port. 
WARNING: Never look at the transmit LED/laser through a magnifying device 
while it is powered on. Never look directly at the fiber TX port and fiber cable ends 
when they are powered on.
General Site 
Requirements
The environment of the installation site influences the performance and lifetime of 
the switch. The installation site for your switch should meet the requirements 
described in the following sections.
Temperature and Humidity
To ensure normal operation and to prolong the operational lifetime of the switch, 
the temperature and humidity of the equipment room must be within controlled 
limits. The requirements for the temperature and humidity of the switch 
installation site are listed in Table 41.