3com Webcache 1000 (3C16115) User Manual

Page of 176
140
A
PPENDIX
 A: S
AFETY
 I
NFORMATION
Important Safety 
Information
Installation and removal of the unit must be carried out by qualified 
personnel only.
The unit must be earthed (grounded).
The unit must be connected to an earthed (grounded) outlet to comply 
with European safety standards and EMC standards.
Power Cord Set
This must be approved for the country where it is used:
This unit operates under SELV (Safety Extra Low Voltage) conditions 
according to IEC 950. The conditions are only maintained if the 
equipment to which it is connected also operates under SELV conditions.
The appliance coupler (the connector to the unit and not the wall plug) 
must have a configuration for mating with an EN60320/IEC320 appliance 
inlet.
The socket outlet must be near to the unit and easily accessible. You can 
only remove power from the unit by disconnecting the power cord from 
the outlet.
UK
The supply plug must comply with BS1363 (3-pin 13 
amp) and be fitted with a 5A fuse which complies with 
BS1362.
The mains cord must be <HAR> or <BASEC> marked 
and be of type HO3VVF3gO.75 (minimum).
Europe
The supply plug must comply with CEE 7/7 
(“SCHUKO”).
The supply plug must comply with CE123-16/VII.
USA and 
Canada
The cord set must be UL-approved and CSA certified.
The minimum specification for the flexible cord is:
No. 18 AWG
Type SV or SJ
3-conductor
The cord set must have a rated current capacity of at 
least 10A.
The attachment plug must be an earth-grounding type 
with a NEMA 5-15P (15A, 125V) or NEMA 6-15P (15A, 
250V) configuration.
Denmark
The supply plug must comply with section 107-2-D1, 
standard DK2-1a or DK2-5a.
Switzerland
The supply plug must comply with SEV/ASE 1011.